2 NOV2018
  Central Government/Public Sector
Central Government/Public Sector jamalpur-bihar
Ref. No : 14439509
10/23/2018 12:00:00 AM Tender Value : NA 0.00 Sector : Railway Transport

Supply Of Inverter Lh Ac Cyclonic Filter Exhauster Motor Lh Specn.Rdsos Specn. No.- Mp.0.24.00.20 Rev-01, July 2008 And Mod Sheet No. Mp.Mod.Em.02.04.11 Rev-00 Dt.21-04- 2011.

2 NOV2018
  Central Government/Public Sector
Central Government/Public Sector gurgaon-haryana
Ref. No : 14430625
10/22/2018 12:00:00 AM Tender Value : NA 0.00 Sector : Health Services/Equipments

Supply, Installation, Testing And Commissioning Of Eeg Equipment - Brand New Electroencephalograph Uses Electrodes Placed On A Patient’S Scalp To Measure, Amplify, Display In Graphic Form, And Record The Weak Electrical Signals Generated By The Brain. Electroencephalography Is Useful In Observing And Diagnosing A Variety Of Neurologic Conditions, Including Epilepsy, Related Convulsive Disorders, And Brain Death. It Can Also Be Used To Evaluate Psychiatric Disorders And Differentiate Among Various Psychiatric And Neurologic Conditions. In Addition, Electroencephalographic Studies Can Assist In Localizing Tumors Or Lesions On Or Near The Surface Of The Brain, Eeg System Complete With Software For Acquisition And Review And The Compatible Computer With Necessary Interface And Printer Is Required., 1. Should Be Pc Based With Minimum Following Pc Specifications: Pentium Iv, 512 Mb Ddr Ram, 160 Gb Hdd, Cd/Dvd Rw, 17-25 Lcd Tft Display, Key Board, Mouse And Ups, Number Of Eeg Channels Should Be 32 With Color Coding, And Another Eight Channels For Polygraphy. Also Any Two Channels Can Be Configured As Bipolar, Ac Or Dc Through Software, Facillity For Simultaneous Sampling Of All Eeg Channels And Multiple Sampling Rates, Photic Stimulator With Software Prorammable For Manual Or Automatic Sequences, Networking Facility, Dicom Compatible, 32 Channel Amplifiers Needed, Cmrr Should Be > 110 Db Or Better, Noise < 2Uv Peak To Peak, Input Impedance > 100 Mohm, 16 Bit Adc Resolution Voltage Of 0.153 Uv, Low Filter Adjustable Between 0.16 To 5 Hz, High Filter Adjustable Between 50 To 100Hz, Notch Filter Adjustable To Softwares, Acquisition Sensitivity From 1 Microvolt Per Mm To 2000 Microvolt Per Mm, Networking Facility, Facility To Combine All User Defined Settings Into Templates Or Protocol, For Use In Diffferent Applications, Facility Forindividual Channel Control, Customization Of Montages, Along With Remontage Capabilities, Should Display A Graphical View Of The Current Montage During The Eeg Recording, Facility To Define New Sensors Should Be Possible As Standard I.E Assign To Amplifier Inputs, Define Traces In A Mintage, Define Calclulated Channels Average, Source/Laplacian, Or Define Trends, Facility To Click Any Point To Display Corresponding Traces & Slide Pointer To Change Displayed Duration Of The Overview, Facility For Sortable List Of All Events Placed In The Recording, Both Automatically And Manually, Facility To Review And Add Events To Recorded Traces, Facility For Automatic Time Counters And Fevent Insertion During Hyperventilation, Facility To Controlled Display Sensitivity For User Defined Value, Facility To Choose Low & High Cut Filters Along With Facility To Enter Any User Defined Value, Facility To File Zip, Facility Of Configurable Time Base, Spike & Seizure Software, Trend Analysis Software, Paging Facility As Automatic Paging, Mouse Controlled Paging And/ Or Keyboard Paging, Playback Of Eeg For One Or More Channels, Facility For Zoom/ Magnify Eeg Trace, Facility For Copy & Paste Of Eeg Or Trends To Reports And Presentations, Facility For Automatic Generation Of Reports, Facility For Viewing Several Recordings In Tiled Or Cascading Windows, Network Supported Patient And Test Management Software, Archive To Cd Or Dvd, Powerful Search, Patient Folder, Workspaces, Should Have An Option Of Upgrading The Digital Eeg To Video Eeg With Day/Night Camera Using Mpeg-2 3Rd Generation Technology, Compatible Laser Printer With 600 Dpi Resolution And A4 Size Printing Facility, Standard Accessories To Include The Patient Cable And Connectors With Electrodes And Papers For At Lease 1000 Eeg Exams And All The Necessary Power Cables And Other Interfaces, Optional Requirements Components For Video Eeg Upgradation, The Unit Shall Be Capable Of Being Stored Continuously In Ambient Temperature Of 0 -50 Deg C And Relative Humidity Of 15-90%, The Unit Shall Be Capable Of Being Stored Continuously In Ambient Temperature Of 0 -50 Deg C And Relative Humidity Of 15-90%, Environmental Factors, The Unit Shall Be Capable Of Operating In Ambient Temperature Of 20-30 Deg C And Relative Humidity Of Less Than 70%, Power Supply, Power Input To Be 220-240Vac, 50Hz Fitted With All Over Indian Plug, Resettable Overcurrent Breaker Shall Be Fitted For Protection, Voltage Corrector/Stabilizer Of Appropriate Ratings Meeting Isi Specifications. Input 160- 260 V And Output 220-240 V And 50 Hz, Suitable Ups With Maintenance Free Batteries For Minimum One-Hour Back-Up Should Be Supplied With The System, Standards, Safety And Training, Manufactures/Supplier Should Have Iso Certificate To Quality Standard, Should Be Compliant With Iec 61010-1:Or Any International Equivalent Eg En/Ul 61010 Covering Safety Requirements For Electrical Equipment For Measurement Control And Laboratory Use, Should Be Fda, Ce, Ul Or Bis Approved Product, Comprehensive Training For Lab Staff And Support Services Till Familiarity With The System, Shall Be Certified To Be Meeting The Safety Standards Iec- 60601-2-26 Part 2: Particular Requirements For Safety Of Eeg Systems, User/Technical/Maintenance Manuals To Be Supplied In English, Certificate Of Calibration And Inspection, List Of Equipments Available For Providing Calibration And Routine Maintenance Support As Per Manufacturer Documentation In Service / Technical Manual, List Of Important Spare Parts And Accessories With Their Part Number And Costing, Log Book With Instructions For Daily, Weekly, Monthly And Quarterly Maintenance Checklist. The Job Description Of The Hospital Technician And Company Service Engineer Should Be Clearly Spelt Out, Compliance Report To Be Submitted In A Tabulated And Point Wise Manner Clearly Mentioning The Page/ Para Number Of Original Catalogue/Data Sheet. Any Point, If Not Substantiated With Authenticated Catalogue/Manual, Will Not Be Considered.

19 NOV2018
  Central Government/Public Sector
Central Government/Public Sector kharagpur-west bengal
Ref. No : 14399405
10/16/2018 12:00:00 AM Tender Value : NA 0.00 Sector : Railway Transport

Supply Of Ball Brg. For Ac Fuel Pump Motor 1.5 Hp Commutator & Fan End, Ac Crank Case Motor 0.5 Hp, Fan End & Ac Cyclonic Filter Motor 0.87 Hp. Fan End, Brg. No: 6305 2Rs1-C3 Deep Groove Ball Bearings Single Row With Sealsskf Make Imported.

2 NOV2018
  Central Government/Public Sector
Central Government/Public Sector lucknow-uttar pradesh
Ref. No : 14401571
10/16/2018 12:00:00 AM Tender Value : NA 0.00 Sector : Railway Transport

Supply Of 0.87 H.P. Ac Cyclonic Filter Dust Exhauster Motor

22 OCT2018
  Central Government/Public Sector
Central Government/Public Sector mumbai-maharashtra
Ref. No : 14401883
10/16/2018 12:00:00 AM Tender Value : NA 0.00 Sector : Railway Transport

Supply Of Fresh Air Filter For Lhb Rmpu A.C. Coaches Confirming To Rdso Specification No. Rdso/Pe/Spec/Ac/0055-2003Rev-2With Drg.No. Rdso/Pe/Sk/Ac/0074-2004 Rev 1 Overall Size Of Filter 480 Mm X 260 Mm X 10 Mm Instead Of Size Mentioned In Drg.

27 OCT2018
  Central Government/Public Sector
Central Government/Public Sector bangalore-karnataka
Ref. No : 14401955
10/16/2018 12:00:00 AM Tender Value : NA 0.00 Sector : Education And Research Institutes

Supply Of Ac Filter

27 OCT2018
  Central Government/Public Sector
Central Government/Public Sector bangalore-karnataka
Ref. No : 14397774
10/15/2018 12:00:00 AM Tender Value : NA 0.00 Sector : Education And Research Institutes

Supply Of Ac Filter

31 OCT2018
  Central Government / Public Sector
Central Government / Public Sector angul-orissa
Ref. No : 14388440
10/13/2018 12:00:00 AM Tender Value : NA 0.00 Sector : Railway Transport

Supply Of Filter Media For Return Air For Lhb Type Rmpu Ac Coaches, Size: 1080X420x10mm, Confirming To Rdso Specification No. Rdso/Pe/Spec/Ac/0055-2003, Rev-2, With Rdso Drawing No. Rdso/Pe/Sk/Ac/0073-2004 Rev. 1 .

Related Keywords of Ac Filter


Get Tenders of Ac Filter